Effect of pre-heating on the viscosity and microhardness of a resin composite
Published
()
Optional Fields
resin composite surface hardness viscosity pre-heating ease of placement hardness ratio PRE-HEATED COMPOSITE RHEOLOGICAL PROPERTIES IN-VITRO RESTORATIONS TEMPERATURE CURE POLYMERIZATION MICROLEAKAGE CONVERSION HARDNESS
37
278
282
The effect of pre-heating resin composite on pre-cured viscosity and post-cured surface hardness was evaluated. Groups of uncured specimens were heated to 60 degrees C and compared with control groups (24 degrees C) with respect to viscosity and surface hardness. Mean (SD) viscosities of the pre-heated specimens (n = 15) were in the range of 285 (13)-377 (11) (Pa) compared with 642 (35)-800 (23) (Pa) at ambient temperature. There was a statistically significant difference between the two groups (P < 0 center dot 001). Mean (SD) Vickers microhardness (VHN) of the pre-heated group (n = 15) was 68 center dot 6 (2 center dot 3) for the top surface and 68 center dot 7 (1 center dot 8) for the bottom surface measured at 24 h post curing (specimen thickness = 1 center dot 5 mm). The corresponding values for the room temperature group were 60 center dot 6 (1 center dot 4) and 59 center dot 0 (3 center dot 5). There was a statistically significant difference between corresponding measurements taken at the top and bottom for the pre-heated and room temperature groups (P < 0 center dot 001). There was no significant difference between top and bottom measurements within each group. Pre-heating resin composite reduces its pre-cured viscosity and enhances its subsequent surface hardness. These effects may translate as easier placement together with an increased degree of polymerization and depth-of-cure.
DOI 10.1111/j.1365-2842.2009.02045.x
Grant Details