Peer-Reviewed Journal Details
Mandatory Fields
Merly, C.,Lynch, B.,Ross, P.,Glennon, J. D.;
1998
April
Journal of Chromatography A
Selective ion chromatography of metals on porous graphitic carbon. Journal of Chromatography A
Validated
()
Optional Fields
804
1-2
187
192
The selective retention of trace levels of the transition metal ions, Cu2+ and Pb2+ on a porous graphitic carbon (PGC) column, is described using ion chromatography with acidified aqueous mobile phases, post-column detection using PAR and spectrophotometric detection. PGC is a selective sorbent for Pb2+ and for Cu2+ in aqueous acidified solution, with the latter not eluting from the column. Variation of the concentration of added oxalic acid to the acidified aqueous mobile phase leads to the elution of Cu2+, and ion chromatography of a metal mixture of Ni2+, Cd2+, Pb2+ and Cu2+ is optimised to give baseline resolution. (C) 1998 Elsevier Science B.V.
0021-9673
://000073638400024
Grant Details