Peer-Reviewed Journal Details
Mandatory Fields
O'Sullivan, ACM;Lightbody, G
2017
March
Renewable Energy
Co-design of a wave energy converter using constrained predictive control
Validated
Optional Fields
POWER TAKE-OFF CONTROL STRATEGIES LINEAR GENERATOR LATCHING CONTROL DEVICE SEA OPTIMIZATION SYSTEM FAULT
102
142
156
This paper highlights the need to optimise the performance of the complete wave to wire system, instead of designing the individual subsystems. In this work a point absorber wave energy converter operating in heave mode separately, coupled to a Linear Permanent Magnet Generator (LPMG); where the results are obtained in simulation. The PTO force is controlled by a machine side back-to-back voltage source converter (VSC), which is connected to a constant DC-link voltage. Model Predictive Control-(MPC) is then used to maximise the absorbed electrical power with the resistive losses of the PTO included; this is compared with classical control methods. The optimal force produced from the MPC incorporates legitimate physical and electrical constraints of the WEC and LPMG-the importance of including such constraints within the optimisation is shown. Field weakening and a uni-directional power flow constraint are then incorporated to help prevent poor grid power quality when fluctuations in the DC link occur. It is assumed that the constrained optimal control approach produces the highest possible electrical power available. This means that it is now possible to clearly see the effect of physical design choices on the performance on a level playing field. (C) 2016 Elsevier Ltd. All rights reserved.
OXFORD
0960-1481
10.1016/j.renene.2016.10.034
Grant Details