Current guidelines recommend using Korotkoff phase IV for measuring diastolic blood pressure in pregnant women. However, phase IV does not approximate "true" blood pressure as closely as phase V, is more difficult to detect, and has limited reproducibility. Many practitioners use phase V despite the guidelines. Universal adoption of phase V would improve the reliability of blood pressure measurements.