Peer-Reviewed Journal Details
Mandatory Fields
Roberts, J. T.,Ali, H. H.,Shorten, G. D.;
1993
Journal of clinical anesthesia
USING THE BUBBLE INCLINOMETER TO MEASURE LARYNGEAL TILT AND PREDICT DIFFICULTY OF LARYNGOSCOPY
Validated
()
Optional Fields
5
44
306
309306
Study Objective: To evaluate a simple device, the bubble inclinometer, to measure degrees of laryngeal tilt (LT) for predicting difficulty of direct laryngoscopy using a Macintosh #3 laryngoscope. Design: Randomized, double-blind study. Setting: Inpatient surgery center at a university medical center. Patients: 50 renal lithotripter patients. Interventions: Patients were measured with the bubble inclinometer and the laryngeal indices caliper. A sleep dose of thiopental sodium (4 mg/kg) and a muscle-relaxing dose of succinylcholine (1 mg/kg) were then given to each patient. Measurements and Main Results: LT was measured by both methods (directly and indirectly). Difficulty of laryngoscopy was graded as follows: Grade 1 = all of vocal cords seen; Grade 2 = part of vocal cords seen; Grade 3 = no part of vocal cords seen. Conclusions: The bubble inclinometer accurately and reproducibly measures relative LT, and the anterior tilt of the larynx directly correlates with the ability to see the laryngeal opening during direct laryngoscopy with a Macintosh #3 laryngoscope.Study Objective: To evaluate a simple device, the bubble inclinometer, to measure degrees of laryngeal tilt (LT) for predicting difficulty of direct laryngoscopy using a Macintosh #3 laryngoscope. Design: Randomized, double-blind study. Setting: Inpatient surgery center at a university medical center. Patients: 50 renal lithotripter patients. Interventions: Patients were measured with the bubble inclinometer and the laryngeal indices caliper. A sleep dose of thiopental sodium (4 mg/kg) and a muscle-relaxing dose of succinylcholine (1 mg/kg) were then given to each patient. Measurements and Main Results: LT was measured by both methods (directly and indirectly). Difficulty of laryngoscopy was graded as follows: Grade 1 = all of vocal cords seen; Grade 2 = part of vocal cords seen; Grade 3 = no part of vocal cords seen. Conclusions: The bubble inclinometer accurately and reproducibly measures relative LT, and the anterior tilt of the larynx directly correlates with the ability to see the laryngeal opening during direct laryngoscopy with a Macintosh #3 laryngoscope.
0952-81800952-8180
://WOS:A1993LR75700010://WOS:A1993LR75700010
Grant Details